skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: 5MW Raft River facility experience

Conference ·
OSTI ID:5319956

The Raft River geothermal plant is a small binary cycle conversion system which uses isobutane as the working fluid. This plant uses a staged boiler concept to achieve better performance than could be obtained by a single boiler. The plant was designed to operate with a geothermal water inlet temperature of 143/sup 0/C (290/sup 0/F) and produce a nominal generator output of 5MW. The plant is supported by a supply and injection system consisting of three supply wells (about 1524m or 5000 ft deep) and two injection wells (about 1158m or 3800 ft deep). Experience in several important areas: environmental, supply and injection system, and power plant, are discussed. (MHR)

Research Organization:
EG and G Idaho, Inc., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
5319956
Report Number(s):
CONF-800681-1
Resource Relation:
Conference: EPRI geothermal workshop, Monterey, CA, USA, 23 Jun 1980
Country of Publication:
United States
Language:
English