Effect of tube-support interaction on the dynamic responses of heat exchanger tubes. [LMFBR]

Conference ·
OSTI ID:5319282
Operating heat exchangers have experienced tube damages due to excessive flow-induced vibration. The relatively small inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the tube vibrational characteristics. In attempting a theoretical analysis, questions arise as to the effects of tube-baffle impacting on dynamic responses. Experiments were performed to determine the effects of tube-baffle impacting in vertical/horizontal tube orientation, and in air/water medium on the vibrational characteristics (resonant frequencies, mode shapes, and damping) and displacement response amplitudes of a seven-span tube model. The tube and support conditions were prototypic, and overall length approximately one-third that of a straight tube segment of the steam generator designed for the CRBR. The test results were compared with the analytical results based on the multispan beam with ''knife-edge'' supports.
Research Organization:
Argonne National Lab., Ill. (USA)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
5319282
Report Number(s):
CONF-770807-51
Country of Publication:
United States
Language:
English

Similar Records

Vibro-impact responses of a tube with tube--baffle interaction. [LMFBR]
Technical Report · Sat Dec 31 23:00:00 EST 1977 · OSTI ID:5056428

Vibration damping in multispan heat exchanger tubes
Journal Article · Sat Aug 01 00:00:00 EDT 1998 · Journal of Pressure Vessel Technology · OSTI ID:655475

Flow-induced vibration in shell-and-tube heat exchangers with double-segmental baffles
Journal Article · Tue Dec 31 23:00:00 EST 1985 · Heat Transfer Eng.; (United States) · OSTI ID:6555306