Prediction of GE-ATLAS transient boiling transition data using RETRAN-02/RETRAN-15F
Journal Article
·
· Nucl. Technol.; (United States)
OSTI ID:5316079
The steady-state operating limit for boiling water reactors (BWRs) is determined by calculating the transient change in the critical power ratio (CPR). To determine the operating limit CPR, a method for calculating the ..delta..CPR during transients is needed. The RETRAN code can be used as a tool in the evaluation of transient CPRs for determining the operating margin for BWRs. Since the RETRAN code does not contain a critical power calculation, the ..delta..CPR cannot be obtained directly from RETRAN. Therefore, a program, TCPYA01, designed to evaluate transient CPR (and ..delta..CPR) based on the GEXL correlation using time-dependent conditions from RETRAN was used. The justification for using the RETRAN code is provided by predicting transient boiling transition data taken at the GE-ATLAS loop facility. Results of the sensitivity studies performed on nodalization, void models, and time-step size are also provided.
- Research Organization:
- Yankee Atomic Electric Company, 1671 Worcester Road, Framingham, Massachusetts 01701
- OSTI ID:
- 5316079
- Journal Information:
- Nucl. Technol.; (United States), Journal Name: Nucl. Technol.; (United States) Vol. 61:2; ISSN NUTYB
- Country of Publication:
- United States
- Language:
- English
Similar Records
Analysis of cofrentes abnormal plant transients with RETRAN-02 and RETRAN-03
Assessment of RETRAN-3D Boiling Models Against Experimental Subcooled Boiling Tube Data
The Analysis of Pressurized Water Reactor and Boiling Water Reactor Reactivity Transients with CORETRAN and RETRAN-3D
Journal Article
·
Sat Oct 31 23:00:00 EST 1992
· Nuclear Technology; (United States)
·
OSTI ID:6934116
Assessment of RETRAN-3D Boiling Models Against Experimental Subcooled Boiling Tube Data
Journal Article
·
Tue Apr 15 00:00:00 EDT 2003
· Nuclear Technology
·
OSTI ID:20826842
The Analysis of Pressurized Water Reactor and Boiling Water Reactor Reactivity Transients with CORETRAN and RETRAN-3D
Journal Article
·
Tue Apr 15 00:00:00 EDT 2003
· Nuclear Technology
·
OSTI ID:20826840
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
210100* -- Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
BOILING
BWR TYPE REACTORS
COMPUTER CODES
PHASE TRANSFORMATIONS
R CODES
REACTORS
STEADY-STATE CONDITIONS
T CODES
TRANSIENTS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210100* -- Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
BOILING
BWR TYPE REACTORS
COMPUTER CODES
PHASE TRANSFORMATIONS
R CODES
REACTORS
STEADY-STATE CONDITIONS
T CODES
TRANSIENTS
WATER COOLED REACTORS
WATER MODERATED REACTORS