Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Determination of gold--copper alloy composition by x-ray fluorescence analysis. Final report. [In-process analysis of electroplate]

Technical Report ·
DOI:https://doi.org/10.2172/5312240· OSTI ID:5312240
A method for in-process determination of the composition of electroplated gold-copper alloys using x-ray fluorescence analysis has been developed. A source-excited, non-dispersive x-ray fluorescence analyzer was procured and developed for this purpose. A set of calibration standards was procured, and a calibration curve was constructed by plotting a ratio of x-ray fluorescence intensities against known alloy composition. This technique is now being used as the primary method for in-process alloy measurements during gold-copper electroplating. It replaces a previously used technique involving the calculation of the mass density of the plated deposit. The x-ray technique has been shown to measure alloy composition to an overall precision of +-0.12 wt% using two-minute counting times. Post-plate D-tests of parts from full length plating runs show the x-ray technique to agree with electron microprobe analysis within the limits of precision.
Research Organization:
Bendix Corp., Kansas City, Mo. (USA)
DOE Contract Number:
EY-76-C-04-0613
OSTI ID:
5312240
Report Number(s):
BDX-613-1716(Rev.)
Country of Publication:
United States
Language:
English