Experiment data report for Semiscale Mod-1 test S-28-3 (steam generator tube rupture test). [PWR]

Technical Report ·
DOI:https://doi.org/10.2172/5309950· OSTI ID:5309950
Recorded test data are presented for Test S-28-3 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-3 was conducted from initial conditions of 15621 kPa and 555 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Twelve steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg.
Research Organization:
EG and G Idaho, Inc., Idaho Falls (USA)
DOE Contract Number:
EY-76-C-07-1570
OSTI ID:
5309950
Report Number(s):
TREE-NUREG-1150
Country of Publication:
United States
Language:
English