skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Polarimeters for the AGS polarized proton beam

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:5302072

This report describes the three polarimeters which will be used to measure the beam polarization at the AGS polarized beam facility. The beam polarization will be measured before injection into the AGS, during acceleration, and after extraction from the AGS. The 200 MeV polarimeter uses scintillation counter telescopes to measure the asymmetry in p-carbon inclusive scattering. The internal polarimeter can measure the beam polarization at up to five selected times during acceleration. A continuously spooled nylon filament is swung into the beam at the appropriate time and the asymmetry in pp elastic scattering measured by two scintillation counter telescopes. This is a relative polarimeter which can be calibrated by the absolute external polarimeter located in the ''D'' extracted beam line. This polarimeter uses scintillation counters in two double-arm magnetic spectrometers to measure clearly the asymmetry in pp elastic scattering from a liquid hydrogen target. The specific features and operation of each polarimeter are discussed.

Research Organization:
Accelerator Department, Brookhaven National Laboratory, Associated Universities, Inc., Upton, New York 11973
OSTI ID:
5302072
Report Number(s):
CONF-830311-
Journal Information:
IEEE Trans. Nucl. Sci.; (United States), Vol. NS-30:4; Conference: Particle accelerator conference, Santa Fe, NM, USA, 21 Mar 1983
Country of Publication:
United States
Language:
English