Guarded hot plate and heat flow meter methodology
                            Conference
                            ·
                            
                            
                            
                    
                                
                                OSTI ID:5296643
                                
                            
                        This book compiles papers presented at a conference on thermal insulation. The subject of the conference was guarded hot plate and heat flow meter methodology. Some of the topics included are: thermal conductance of liquefied gas tank insulation; heat flow meter apparatus and transfer standards used for error analysis; present and future research on guarded hot plate and heat flow meter apparatus; and field measurements of thermal transfer properties of insulation systems. The guarded hot plat method is described for measuring the thermal conductivity of thermal insulations and materials of low thermal conductivity.
- OSTI ID:
- 5296643
- Report Number(s):
- CONF-8210209--; ISBN: 0-8031-0423-5
- Country of Publication:
- United States
- Language:
- English
Similar Records
                                
                                
                                    
                                        
                                        Design of round-robin tests with guarded/calibrated hot boxes, guarded hot plates, and heat flow meters
                                        
Calibration at 24{degrees}C of a heat-flow-meter apparatus having 610 mm square plates
Calibration at 24 degrees C of a heat-flow-meter apparatus having 610 mm square plates
                        
                                            Conference
                                            ·
                                            Fri Dec 31 23:00:00 EST 1982
                                            · Am. Soc. Test. Mater., Spec. Tech. Publ.; (United States)
                                            ·
                                            OSTI ID:6689456
                                        
                                        
                                        
                                    
                                
                                    
                                        Calibration at 24{degrees}C of a heat-flow-meter apparatus having 610 mm square plates
                                            Technical Report
                                            ·
                                            Wed May 01 00:00:00 EDT 1991
                                            
                                            ·
                                            OSTI ID:10155692
                                        
                                        
                                        
                                    
                                
                                    
                                        Calibration at 24 degrees C of a heat-flow-meter apparatus having 610 mm square plates
                                            Technical Report
                                            ·
                                            Wed May 01 00:00:00 EDT 1991
                                            
                                            ·
                                            OSTI ID:5291351