This paper presents the results of a continuing investigation into degradation of the crosslinked polyethylene (XLPE) cable insulation. The paper deals with the changing of water absorption of various types of XLPE cable insulations: steam and nitrogen-dry cured crosslinked polyethylene (XL) and steam and nitrogen-dry cured water tree retardant crosslinked polyethylene (WTR-XL). The results of the study into effect of water absorption on breakdown stress (AC BDS) and partial discharge for different XLPE cable insulations are also given. During the aging tests, the cable conductor was poured with the tap water and the cable ends were properly closed.

OSTI ID:
529592
Report Number(s):
CONF-960614--; ISBN 0-7803-3531-7
Country of Publication:
United States
Language:
English

Similar Records

Low temperature aging of XLPE and EP insulated cables with voltage transients
Journal Article · Sat Dec 31 23:00:00 EST 1994 · IEEE Transactions on Power Delivery · OSTI ID:39967

Water tree retardant XLPE cable using VLDPE
Journal Article · Fri Dec 31 23:00:00 EST 1993 · IEEE Transactions on Power Delivery (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:7046301

Electrical-breakdown characteristics and testing of high-voltage XLPE- and EPR-insulated cables