Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Base-line data analysis of a developing geothermal system, Boise, Idaho

Technical Report ·
OSTI ID:5293320
The report covers a geothermal system and calculated aquifer transmissivities in the Boise Warm Springs Water District portion of the geothermal system range from 3500-25,000 gals/day/ft. Withdrawals during the 1984-1985 heating season stabilized drawdown at the pumpbowls, and water levels approached stability in observation wells as distant as 1675 ft (507.6m). In the near steady-state condition, recharge, and water from storage beyond the observation wells provided a maximum Q of 840 gpm.
Research Organization:
Idaho Univ., Moscow (USA). Water Resources Research Inst.
OSTI ID:
5293320
Report Number(s):
PB-86-198074/XAB
Country of Publication:
United States
Language:
English

Similar Records

Boise geothermal system, western Snake River plain, Idaho
Conference · Sun Jul 01 00:00:00 EDT 1984 · Am. Assoc. Pet. Geol., Bull.; (United States) · OSTI ID:5532580

Aquifer evaluation at Fenton Hill, October and November 1980
Technical Report · Thu Oct 01 00:00:00 EDT 1981 · OSTI ID:6120603

Boise Geothermal Aquifer Study
Technical Report · Sun Dec 31 23:00:00 EST 1989 · OSTI ID:6460627