Beam stability at SRRC storage ring
Conference
·
OSTI ID:52869
- Synchrotron Radiation Research Center, Hsinchu (Taiwan, Province of China); and others
To satisfy the need of users of the synchrotron radiation at SRRC, the photon flux at the end station has to be kept at a constant with minimum fluctuation. The sources of flux variation attributable to the electron beam in the storage ring have been carefully studied and the effects on the flux have been investigated. The sources include floor vibration, power supply ripples, cooling water, ion trapping and transverse instability. The cures attempted or in plan include removal of vibration sources, reduction of ripple, local orbit feedback, ion cleaning and damping. A special diagnostic beamline has been constructed and used solely for accelerator studies and improvements.
- Research Organization:
- Brookhaven National Lab., Upton, NY (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States); National Science Council, Taipei (Taiwan, Province of China)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 52869
- Report Number(s):
- BNL--61719; CONF-950512--21; ON: DE95010842
- Country of Publication:
- United States
- Language:
- English
Similar Records
Damping rates of the SRRC storage ring
Performance of the SRRC storage ring and wiggler commissioning
Diagnostics development in SRRC
Conference
·
Thu Jun 01 00:00:00 EDT 1995
·
OSTI ID:72993
Performance of the SRRC storage ring and wiggler commissioning
Conference
·
Mon May 01 00:00:00 EDT 1995
·
OSTI ID:70705
Diagnostics development in SRRC
Journal Article
·
Wed Dec 09 23:00:00 EST 1998
· AIP Conference Proceedings
·
OSTI ID:21202398