SNAP 19 Viking Program. Bimonthly technical progress report, June-July 1980

Technical Report ·
DOI:https://doi.org/10.2172/5284239· OSTI ID:5284239
Monitoring and evaluation of Viking Lander 1 power system data continued. The RTG series power range as measured at the PCDA was 64 to 66 watts at finroot temperatures between 270/sup 0/F and 310/sup 0/F. Figures show the Mars Lander performance history of Viking 1. These data include both the minimum and maximum data for each of the SOL days plotted to show the range of performance experienced on the Martian surface. Power system performance data for Pioneer 10 and Pioneer Saturn (initially designated Pioneer 11) were monitored through the reporting period and are shown. After adjusting for the telemetry characteristics, the estimated RTG system net power was 114 watts for both, Pioneer 10 and Pioneer Saturn.
Research Organization:
Teledyne Energy Systems, Timonium, MD (USA)
DOE Contract Number:
AC01-80ET32066
OSTI ID:
5284239
Report Number(s):
TES-32066-5; ON: DE84010245
Country of Publication:
United States
Language:
English