Comments on the impedances of the SSC shielded bellows at low frequencies due to the truncation of the wake fields
Conference
·
OSTI ID:5276185
The behavior of the longitudinal impedance of the SSC shielded bellow at low frequencies depends very much on the length of the wake field used in the Fourier transformation. We show analytically and numerically that, regardless of the difference, single-bunch effects are independent of the actual shape of the impedance when the length of the wake used is bigger than the bunch length.
- Research Organization:
- Fermi National Accelerator Lab., Batavia, IL (USA)
- DOE Contract Number:
- AC03-76SF00515
- OSTI ID:
- 5276185
- Report Number(s):
- FNAL-TM-1416; CONF-8606215-2; ON: DE87000088
- Country of Publication:
- United States
- Language:
- English
Similar Records
Bellows Wake Fields and Transverse Single Bunch Instabilities in the SSC
Impedances of the shielded bellows in the SSC and the effects on beam stability
Estimate of the contributions of bellows to the impedances and beam instabilities of the SSC
Technical Report
·
Tue Dec 31 23:00:00 EST 1985
·
OSTI ID:1447882
Impedances of the shielded bellows in the SSC and the effects on beam stability
Technical Report
·
Mon Jul 01 00:00:00 EDT 1985
·
OSTI ID:5442405
Estimate of the contributions of bellows to the impedances and beam instabilities of the SSC
Technical Report
·
Mon Jul 01 00:00:00 EDT 1985
·
OSTI ID:5442404