Title: Intensity measurement of high-energy heavy ions at the GSI facility

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.52298· OSTI ID:526819
 [1];  [1];  [1]
  1. Gesellschaft fuer Schwerlonenforschung, Planckstrasse 1, D-64291 Darmstadt (Germany)

The intensity of the high-energy heavy ion beam, extracted from the heavy ion synchrotron (SIS) at the GSI, Darmstadt, is determined with three types of detectors: scintillator counters, ionisation chambers (ICs), and secondary electron monitors (SEMs). The accuracy of the ICs, compared to a general formula, is about 25{percent}; for the SEMs it is within a factor of two. Intensity limits for the IC are measured. A SQUID-based current comparator is in preparation for an absolute determination of the primary ion current. {copyright} {ital 1997 American Institute of Physics.}

OSTI ID:
526819
Report Number(s):
CONF-9605173-; ISSN 0094-243X; TRN: 97:016899
Journal Information:
AIP Conference Proceedings, Vol. 390, Issue 1; Conference: 7. workshop on beam instrumentation, Argonne, IL (United States), 6-9 May 1996; Other Information: PBD: Jan 1997
Country of Publication:
United States
Language:
English