Evaluation of the technological feasibility, and cost of selected control alternatives necessary to meet the proposed Ohio SO/sub 2/ regulations for industrial boilers and processes. Volume IV. E. I. Dupont de Nemours and Company, Cleveland sulfuric acid plant. Final report

Technical Report ·
OSTI ID:5266757
This report presents an evaluation by the GCA Corporation, GCA/Technology Division, of technological feasibility and cost of complying with the proposed Ohio sulfur dioxide regulation (40 FR 52410, November 10, 1975) at the E. I. Dupont de Nemours and Company's Cleveland sulfuric acid plant. The final USEPA Sulfur Dioxide Control Strategy for the State of Ohio Technical Support Documents, Vol. I and II, (EPA 905/2-76-002) may be obtained from NTIS. After collecting the necessary site and process specific data by means of a plant visit, the evaluation was made emphasizing three commercially available sulfur dioxide abatement systems: Union Carbide's 'Pua Sio S' process, the Wellman-Lord system by Davy Powergas, and Dupont's 'Tysul' system.
Research Organization:
GCA Corp., Bedford, Mass. (USA). GCA Technology Div.
OSTI ID:
5266757
Report Number(s):
PB-268957; GCA-TR-14-G-Vol-4
Country of Publication:
United States
Language:
English