Validation of models of gas holdup in the CORCON code

Technical Report ·
OSTI ID:5264285
; ;  [1]
  1. Sandia National Labs., Albuquerque, NM (USA)

Gas holdup data for oleci acid at 291 K and for 1018 steel at 1823 K has been taken for nitrogen sparging gas. The liquid levels have been measured using a real time x-ray technique. The data have been compared to correlations from the literature to assess the appropriate correlations for use in calculating gas holdup for molten core debris in reactor accident calculations. A suitable correlation has been determined as well as coefficients for use in a drift flux model. The correlation is in the form {alpha} = 0.128 M{sup -0.0207} jg*{sup 0.584} where {alpha} is holdup, M is the Morton Number and jg* is the dimensionless gas flux through the liquid. 19 refs., 9 figs., 9 tabs.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (USA). Div. of Systems Research; Sandia National Labs., Albuquerque, NM (USA)
Sponsoring Organization:
NRC
DOE Contract Number:
AC04-76DP00789
OSTI ID:
5264285
Report Number(s):
NUREG/CR-5433; SAND--89-1951; ON: TI90004946
Country of Publication:
United States