Condensate polishing at Plant Bowen

Technical Report ·
OSTI ID:5263931

Condensate polisher system design and operation were evaluated at the fosssil-fueled Plant Bowen of Georgia Power Company relative to the ability of the polishers to achieve an effluent chemical quality consistent with PWR Steam Generator Owners Group Chemistry Guidelines. Polishers regenerated employing the Seprex and Ammonex processes were evaluated during normal plant operation and during periods of simulated condenser inleakage. Although polisher effluent quality was acceptable relative to boiler corrosion control at Plant Bowen, it was inconsistent with that required for recirculating PWR steam generators. Polisher effluent quality was reasonably consistent with requirements for PWR once-through steam generator systems. High polisher cation to anion resin equivalence ratios (3.4 to 1), and insufficiently rapid anion resin kinetics were the major reasons for the observed non-optimum polisher performance.