Title: Radiologic safety assessment for low level waste storage on TRU pads

Technical Report ·
OSTI ID:5262372

The reference document (TA 2-1118) proposes to store Low Level Radioactive Solid Waste in B-25 boxes on concrete pads at the 643-G burial ground site, pending resolution of policy concernig its ultimate disposal. This analysis verifies that the reference proposal is safe, as long as it is applied to a limited material quantity of low specific activity, as described in the reference document. The predominant concern in the safety analysis is the emission of airborne activity as a result of tornados and fires. However, containment provided by B-25 boxes is sufficient to mitigate the consequences of these events sufficiently. Nevertheless, it is strongly recommended that any above-ground storage procedures include provisions for covering the waste containment boxes to prevent exposure to rainwater and subsequent corrosion if the storage period is to extend beyond one year.

Research Organization:
Savannah River Lab., Aiken, SC (USA). Technical Div.
DOE Contract Number:
AC09-76SR00001
OSTI ID:
5262372
Report Number(s):
DPST-86-336; ON: DE86015867
Country of Publication:
United States
Language:
English