Baker Construction, Cincinnati, Ohio. Solar energy system performance evaluation, October 1980-May 1981

Technical Report ·
DOI:https://doi.org/10.2172/5247624· OSTI ID:5247624
The Baker Construction site is a single family residence in Ohio with a passive solar heating system, which consists of 302 square feet of 62 degree sloped greenhouse glazing, a 35,500-pound concrete mass wall, 10,400-pound concrete slab floor, 20 phase change storage rods, six 1-kW electric baseboard heaters, and a wood stove. A solar fraction of 55% is reported. Also the solar savings ratio and conventional fuel savings are given. The performance of the greenhouse collector subsystem, the heat storage subsystem, and the space heating subsystem are summarized as well as total system performance. Energy savings and weather data are also included. The design of the system, performance evaluation techniques, and sensor technology are also presented. (LEW)
Research Organization:
Automation Industries, Inc., Silver Spring, MD (USA). Vitro Labs. Div.
DOE Contract Number:
AC01-79CS30027
OSTI ID:
5247624
Report Number(s):
SOLAR/1095-81/14; ON: DE82007151
Country of Publication:
United States
Language:
English