skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Health hazard evaluation report No. HETA 81-319-1114, Inmos Corporation, Colorado Springs, Colorado

Technical Report ·
OSTI ID:5245396

On July 15, 1981, a NIOSH industrial hygienist collected breathing-zone and general room air samples for normal butyl acetate, cellosolve acetate, xylene, and isopropanol, and general room samples for hydrogen fluoride. All samples were either below laboratory detection limits or well within the evaluation criteria established for this report. None of the workers were receiving any exposure. Noise measurements were taken on twelve workers in the Clean Room. Their exposures averaged less than 80 dBA. At no time during the work cycle was the evaluation criterion of 85 dBA exceeded. None of the workers had work associated health complaints. NIOSH investigators concluded that a health hazard did not exist at the time of this survey.

Research Organization:
National Inst. for Occupational Safety and Health, Cincinnati, OH (USA)
OSTI ID:
5245396
Report Number(s):
PB-84-140664
Country of Publication:
United States
Language:
English