Apportionment of residential indoor VOC's and aldehydes to indoor and outdoor sources in Roanoke
Technical Report
·
OSTI ID:5231762
The average concentrations of a large number of VOC and aldehyde species measured in ten Roanoke, Virginia residences in wintertime have been apportioned according to their contributions from all inside sources and all outside sources. The two category apportionment was accomplished through the use of the single chamber mass balance indoor air quality model given by Dockery and Spengler. While the indoor concentration of some VOC's appeared entirely due to infiltration, most aldehydes had substantial indoor sources. Some homes exhibited very large indoor sources for a few VOC species and two homes appeared contaminated by gasoline vapors. The overall contribution of indoor and outdoor sources to the concentrations of VOC's inside the Roanoke homes is similar to that observed in Boise, ID in a previous study.
- Research Organization:
- Environmental Protection Agency, Research Triangle Park, NC (United States). Atmospheric Research and Exposure Assessment Lab.
- OSTI ID:
- 5231762
- Report Number(s):
- PB-91-219162/XAB
- Country of Publication:
- United States
- Language:
- English
Similar Records
Apportionment of residential indoor aerosol, VOC, and aldehyde species to indoor and outdoor sources, and their source strengths
Apportionment of residential indoor aerosol, VOC, and aldehyde species to indoor and outdoor sources
Sources of air pollutants indoors: VOC and fine-particulate species
Technical Report
·
Tue Dec 31 23:00:00 EST 1991
·
OSTI ID:7160380
Apportionment of residential indoor aerosol, VOC, and aldehyde species to indoor and outdoor sources
Technical Report
·
Sun Dec 31 23:00:00 EST 1989
·
OSTI ID:6557766
Sources of air pollutants indoors: VOC and fine-particulate species
Technical Report
·
Mon Dec 31 23:00:00 EST 1990
·
OSTI ID:5465612
Related Subjects
54 ENVIRONMENTAL SCIENCES
540120* -- Environment
Atmospheric-- Chemicals Monitoring & Transport-- (1990-)
AIR POLLUTION
AIR POLLUTION MONITORING
ALDEHYDES
BUILDINGS
DEVELOPED COUNTRIES
ECOLOGICAL CONCENTRATION
FEDERAL REGION III
INDOOR AIR POLLUTION
MATHEMATICAL MODELS
MATTER
MONITORING
NORTH AMERICA
ORGANIC COMPOUNDS
POLLUTION
POLLUTION SOURCES
RESIDENTIAL BUILDINGS
USA
VIRGINIA
VOLATILE MATTER
540120* -- Environment
Atmospheric-- Chemicals Monitoring & Transport-- (1990-)
AIR POLLUTION
AIR POLLUTION MONITORING
ALDEHYDES
BUILDINGS
DEVELOPED COUNTRIES
ECOLOGICAL CONCENTRATION
FEDERAL REGION III
INDOOR AIR POLLUTION
MATHEMATICAL MODELS
MATTER
MONITORING
NORTH AMERICA
ORGANIC COMPOUNDS
POLLUTION
POLLUTION SOURCES
RESIDENTIAL BUILDINGS
USA
VIRGINIA
VOLATILE MATTER