Corrosion resistance of inconel 690 to sodium carbonate, calcium carbonate, and sodium meta silicate at 900 and 1100{degrees}C

Technical Report ·
DOI:https://doi.org/10.2172/522753· OSTI ID:522753
Corrosive attack of Inconel 690 coupons was not observed following 3 day exposure tests to calcium carbonate, sodium carbonate, and sodium meta silicate at 900 {degrees}C. However, melt line attack was evident on coupons exposed to sodium meta silicate and sodium carbonate tested for 3 days at 1100 {degrees}C. In addition, intergranular attack (IGA), approximately 0.67 mils/day, was observed on the Inconel 690 coupon exposed to calcium carbonate at 1100 {degrees}C. Calcium carbonate did not completely remove the glass coating at 950 {degrees}C. In fact, it was comparable to the results obtained by exposing a glass coated coupon at 950 {degrees}C in air. Therefore, calcium carbonate is not recommended for cleaning the DWPF melter pour spout. Both sodium carbonate and sodium meta silicate appear to remove most of the glass. However, these cleaning agents will remain on the metal surface following exposure at 950 {degrees}C resulting in very rough surface and a potential for corrosive attack when heated to 1100 {degrees}C.
Research Organization:
Westinghouse Savannah River Co., Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
522753
Report Number(s):
WSRC-TR--97-0039; ON: DE97008656
Country of Publication:
United States
Language:
English