Mark III LOCA-related hydrodynamic load definition. Generic technical activity B-10
Technical Report
·
OSTI ID:5222698
This report, prepared by the staff of the Office of Nuclear Reactor Regulation and its consultants at the Brookhaven National Laboratory, provides a discussion of LOCA-related suppression pool hydrodynamic loads in boiling water reactor (BWR) facilities with the Mark III pressure-suppression containment design. Its issuance completes NRC Generic Technical Activity B-10, Behavior of BWR Mark III Containment. On the basis of certain large-scale tests conducted between 1973 and 1979, the General Electric Company developed LOCA-related hydrodynamic load definitions for use in the design of the standard Mark III containment. The staff and its consultants have reviewed these load definitions and their bases conclude that, with a few specified changes, the proposed load definitions provide conservative loading conditions. The staff-approved acceptance criteria for LOCA-related hydrodynamic loads are provided in Appendix C of this report.
- Research Organization:
- Nuclear Regulatory Commission, Washington, DC (USA). Office of Nuclear Reactor Regulation
- OSTI ID:
- 5222698
- Report Number(s):
- NUREG-0978; ON: DE84900860
- Country of Publication:
- United States
- Language:
- English
Similar Records
Mark III LOCA-related hydrodynamic load definition. Generic technical activity B-10. Final report
Mark I containment long-term program safety evaluation report, resolution of generic technical activity A-7. Report for February 1977-December 1979
Mark II containment program load evaluation and acceptance criteria; Generic Technical Activity A-8
Technical Report
·
Wed Aug 01 00:00:00 EDT 1984
·
OSTI ID:6469647
Mark I containment long-term program safety evaluation report, resolution of generic technical activity A-7. Report for February 1977-December 1979
Technical Report
·
Tue Jul 01 00:00:00 EDT 1980
·
OSTI ID:6653889
Mark II containment program load evaluation and acceptance criteria; Generic Technical Activity A-8
Technical Report
·
Sat Aug 01 00:00:00 EDT 1981
·
OSTI ID:5389116
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
210100 -- Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900* -- Nuclear Reactor Technology-- Reactor Safety
ACCIDENTS
BWR TYPE REACTORS
FLUID MECHANICS
HYDRODYNAMICS
LOSS OF COOLANT
MECHANICS
REACTOR ACCIDENTS
REACTOR SAFETY
REACTORS
SAFETY
WATER COOLED REACTORS
WATER MODERATED REACTORS
210100 -- Power Reactors
Nonbreeding
Light-Water Moderated
Boiling Water Cooled
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900* -- Nuclear Reactor Technology-- Reactor Safety
ACCIDENTS
BWR TYPE REACTORS
FLUID MECHANICS
HYDRODYNAMICS
LOSS OF COOLANT
MECHANICS
REACTOR ACCIDENTS
REACTOR SAFETY
REACTORS
SAFETY
WATER COOLED REACTORS
WATER MODERATED REACTORS