Development of the plasma generator for a long pulse 10 x 40 neutral beam
Users of fusion devices have identified heating requirements for positive ion based neutral beams to include energies of 80 or 120 kV with pulse length up to 30 s. Additional requirements are low beam divergence (0.3/sup 0/ x 1.0/sup 0/; 1/e half angles), low impurity (less than 1%), high species (over 80% atomic), and cathode lifetime exceeding 5 h of beam operation. Accelerator design remains as an engineering problem, whereas most of the performance goals have required development of the plasma generator. Problems of concern which relate to the performance goals are the heat dissipation, magnetic field configuration, and cathode placement. The plasma generator was tested on TS IIA (the plasma generator testing facility) which does not have beam extraction capability but is used to evaluate efficiency, operating conditions, arc notching characteristics, species, plasma uniformity, and cathode conditioning. The source, consisting of the plasma generator mounted on the long pulse accelerator was mounted on NBETF (Neutral Beam Engineering Test Facility) for beam testing. During beam operation the back-streaming electrons add power to the source and affect the arc operation. Source durability and stability were studied at 80 kV and 40 A of accelerator current (deuterium). The arc efficiency was higher than the value used for the design. Power loading from back-streaming electrons was much less than the design level. With feedback control, plasma density and accel current were constant to +- 2% during 30-s shots. The beam atomic fraction of 84%-88% (deuterium) was slightly higher than measured on TS IIA. Cathode durability was tested by operating over 500, 30-s full shots at 80 kV and 40 A of deuterium. Arc conditioning was found to be an important phase to avoid filament damage.
- Research Organization:
- Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 5207268
- Journal Information:
- Rev. Sci. Instrum.; (United States), Vol. 57:11
- Country of Publication:
- United States
- Language:
- English
Similar Records
Increased power delivery from the DIII-D neutral beam injection system
120-kV testing of a 10 x 40-cm prototype of the U. S. common long pulse neutral beam source
Related Subjects
NEUTRAL BEAM SOURCES
DESIGN
OPERATION
PERFORMANCE TESTING
ACCELERATORS
BEAM INJECTION
BEAM INJECTION HEATING
ION SOURCES
LAWRENCE BERKELEY LABORATORY
NEUTRAL ATOM BEAM INJECTION
PLASMA
HEATING
NATIONAL ORGANIZATIONS
PLASMA HEATING
TESTING
US AEC
US DOE
US ERDA
US ORGANIZATIONS
700205* - Fusion Power Plant Technology- Fuel
Heating
& Injection Systems