Accuracy of lumbar spine bone mineral content by dual photon absorptiometry
Journal Article
·
· J. Nucl. Med.; (United States)
OSTI ID:5205328
The accuracy of measurement of the bone mineral content (BMC, g) and bone mineral density (BMD, g/cm/sup 2/) of the lumbar spine by dual photon absorptiometry (DPA) was estimated by means of two different spine scanners (a Nuclear Data 2100 and a Lunar Radiation DP3). The lumbar spines of 13 cadavers were used. BMC and BMD were measured in situ and on the excised vertebrae in a solution of water/ethanol; and covered with ox muscle/porcine muscle/lard. The actual mineral weight and areal density were determined after chemical maceration, fat extraction, drying to a constant weight, ashing for 24 hr at 600 degrees C, and correction for the transverse processes. The true are was measured by parallax free X rays and planimetry. All measurements of BMC or BMD were highly interrelated (r = 0.94-0.99). The standard error of estimate (s.e.e.) of BMC in situ versus BMC in water/ethanol was 5.2%. The agreement between the BMD values of the two scanners was very good (s.e.e. = 2.9%). BMC in situ predicted the actual vertebral mineral mass with an s.e.e. of 8.1%. BMD in situ and BMD in water/ethanol predicted the actual area density with s.e.e.s of 10.3% and 5.0%, respectively. This study discloses the correlation and accuracy error of spinal DPA measurements in situ in whole cadavers versus the actual BMC and BMD. The error, which is underestimated in in vitro studies, amounts to 10%.
- Research Organization:
- Univ. of Copenhagen (Denmark)
- OSTI ID:
- 5205328
- Journal Information:
- J. Nucl. Med.; (United States), Journal Name: J. Nucl. Med.; (United States) Vol. 29:2; ISSN JNMEA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Accuracy of dual photon absorptiometry in excised femurs
Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine
Quantitation of bone mineral by dual photon absorptiometry (DPA): Evaluation of instrument performance
Journal Article
·
Mon Oct 31 23:00:00 EST 1988
· J. Nucl. Med.; (United States)
·
OSTI ID:6601767
Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine
Journal Article
·
Mon Oct 31 23:00:00 EST 1988
· Mayo Clin., Proc.; (United States)
·
OSTI ID:6516055
Quantitation of bone mineral by dual photon absorptiometry (DPA): Evaluation of instrument performance
Conference
·
Sat Dec 31 23:00:00 EST 1983
· J. Nucl. Med.; (United States)
·
OSTI ID:6860579
Related Subjects
550602* -- Medicine-- External Radiation in Diagnostics-- (1980-)
62 RADIOLOGY AND NUCLEAR MEDICINE
ABSORPTION SPECTROSCOPY
BIOLOGICAL ACCUMULATION
BIOMEDICAL RADIOGRAPHY
BODY
CHEMICAL COMPOSITION
DIAGNOSTIC TECHNIQUES
ELECTROMAGNETIC RADIATION
ERRORS
IONIZING RADIATIONS
MEDICINE
MINERALS
NUCLEAR MEDICINE
ORGANS
RADIATIONS
RADIOLOGY
SKELETON
SPECTROSCOPY
VERTEBRAE
X RADIATION
62 RADIOLOGY AND NUCLEAR MEDICINE
ABSORPTION SPECTROSCOPY
BIOLOGICAL ACCUMULATION
BIOMEDICAL RADIOGRAPHY
BODY
CHEMICAL COMPOSITION
DIAGNOSTIC TECHNIQUES
ELECTROMAGNETIC RADIATION
ERRORS
IONIZING RADIATIONS
MEDICINE
MINERALS
NUCLEAR MEDICINE
ORGANS
RADIATIONS
RADIOLOGY
SKELETON
SPECTROSCOPY
VERTEBRAE
X RADIATION