Central receiver solar thermal power system, Phase 1. CDRL Item 2. Pilot plant preliminary design report. Volume IV. Receiver subsystem. [10-MW Pilot Plant and 100-MW Commercial Plant]

Technical Report ·
DOI:https://doi.org/10.2172/5199803· OSTI ID:5199803

The conception, design, and testing of the receiver subsystem proposed by the McDonnell Douglas/Rocketdyne Receiver team for the DOE 10-MW Pilot Plant and the 100-MW Commercial Plant are described. The receiver subsystem consists of the receiver unit, the tower on which the receiver unit is mounted above the collector field, and the supporting control and instrumentation equipment. The plans for implementation of the Pilot Plant are given including the anticipated schedule and production plan (procurement, installation, checkout, and maintenance). Specifications for the performance, design, and test requirements for the Pilot Plant receiver subsystem are included. (WHK)

Research Organization:
McDonnell Douglas Astronautics Co., Huntington Beach, CA (USA)
Sponsoring Organization:
USDOE
DOE Contract Number:
EY-76-C-03-1108
OSTI ID:
5199803
Report Number(s):
SAN/1108-8/4; MDC-G-6776(Vol.4)
Country of Publication:
United States