skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A comparison study of commercially-available column flotation technologies

Book ·
OSTI ID:51911
; ;  [1];  [2]
  1. Southern Illinois Univ., Carbondale, IL (United States). Dept. of Mining Engineering
  2. Illinois Clean Coal Inst., Carterville, IL (United States)

A direct comparison of three commercially-available column flotation technologies, i.e., Jameson Cell, Microcel, and Packed-Column, has been conducted using a {minus}100 mesh Illinois No. 5 flotation feed coal sample. The separation performance of each flotation technology was optimized and their performance levels compared on the basis of both ash rejection, sulfur rejection, and throughput capacities. A parametric study using a statistically-designed experimental program was conducted to optimize the critical operating parameter values of each column. The ultimate performance curves for each column were generated by conducting additional tests using the optimized operating parameter values. The throughput capacity of each flotation cell was determined by conducting tests over a range of feed rates at the maximum superficial gas rate while maintaining the other parameters at their optimum values. The separation performance achieved by each of the three flotation cells was found to be comparable to the idealistic flotation performance predicted by release analysis. However, the fraction of wash water reporting to tailings (bias factor) was found to be critical in achieving the near idealistic performance. The bias factor required for the Packed-Column was found to be less than that required by the other two flotation cells. The sulfur rejection achieved by the Microcel and the Packed-Column were found to be greater than that achieved by the Jameson Cell and all three produced sulfur rejections exceeding the values obtained from release analysis. The throughput capacity, on the other hand, differed among the three flotation columns. The Jameson Cell and the Microcel were found to have comparable throughput capacities while the Packed-Column was found to have a lower capacity.

OSTI ID:
51911
Report Number(s):
CONF-940930-; TRN: IM9524%%381
Resource Relation:
Conference: 11. annual international Pittsburgh coal conference: coal, energy and the environment, Pittsburgh, PA (United States), 12-16 Sep 1994; Other Information: PBD: 1994; Related Information: Is Part Of Eleventh annual international Pittsburgh coal conference proceedings: Volume 2; Chiang, S.H. [ed.]; PB: 860 p.
Country of Publication:
United States
Language:
English