Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Ensuring the safety of spillway radial gates

Journal Article · · Hydro Review
OSTI ID:518464
Safety factors pertinent to the design and operation of radial gates on dam spillways are outlined in the article. Sizing considerations discussed include economics and structural flexibility. Safety evaluation and safety considerations are outlined, with special emphasis on trunnion anchorages and seismic evaluation. Maintenance of gate hoists and regular gate inspections are described. An inspection checklist is provided in the article, and six guidelines toward ensuring spillway radial gate safety are identified.
OSTI ID:
518464
Journal Information:
Hydro Review, Journal Name: Hydro Review Journal Issue: 1 Vol. 16; ISSN HYREE8; ISSN 0884-0385
Country of Publication:
United States
Language:
English

Similar Records

Radial gate evaluation: Olympus Dam, Colorado
Technical Report · Sun Jun 01 00:00:00 EDT 1997 · OSTI ID:518744

Radial gate evaluation Angostura Dam, South Dakota
Technical Report · Fri Feb 28 23:00:00 EST 1997 · OSTI ID:479144

Planning a cost-effective gate rehab
Journal Article · Sun Mar 31 23:00:00 EST 1996 · Hydro Review · OSTI ID:244039