LOFT Steam Generator thermal analysis Class I review

Technical Report ·
DOI:https://doi.org/10.2172/5176535· OSTI ID:5176535
A Class 1 review of the thermal analysis of the LOFT Steam Generator and of the transient thermal analysis of LOFT steam generator thermal well was made to confirm compliance of the analyses with the LOFT Technical Specifications, with the LOFT integral test system - preliminary component design description for the steam generator, and with Appendix C of ANC Specification 60139. Included in this review is an examination of the thermal transients and conditions to insure adequate conservatism in analyzed conditions and transients to which the LOFT Steam Generator (including thermal well) might be exposed while in service at the LOFT reactor facility. Also, a review of the thermal code used was made to check for its applicability to these analyses.
Research Organization:
Idaho National Engineering Lab., Idaho Falls (USA)
DOE Contract Number:
EY-76-C-07-1570
OSTI ID:
5176535
Report Number(s):
LTR-1141-32; RE-A-77-107
Country of Publication:
United States
Language:
English