Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Josephson array voltage calibration system; Operational use and verification

Journal Article · · IEEE (Institute of Electrical and Electronics Engineers) Transactions on Instrumentation and Measurement; (USA)
DOI:https://doi.org/10.1109/19.192292· OSTI ID:5169692
;  [1]
  1. National Inst. of Standards and Technology, Gaithersburg, MD (USA)

The authors describe a new Josephson array system which maintains the U.S. Legal Volt. This system is almost fully automated, operates with a typical precision of 0.009 {mu}V, and readily allows U.S. Legal Volt measurements weekly, or more frequently if desired. This system was compared to the previous volt maintenance system, and agreement was made to within 0.03 ppm. This verification is limited by uncertainties in the resistive divider instruments of the previous system.

OSTI ID:
5169692
Journal Information:
IEEE (Institute of Electrical and Electronics Engineers) Transactions on Instrumentation and Measurement; (USA), Journal Name: IEEE (Institute of Electrical and Electronics Engineers) Transactions on Instrumentation and Measurement; (USA) Vol. 38:2; ISSN IEIMA; ISSN 0018-9456
Country of Publication:
United States
Language:
English