Highly selective CO sensor using indium oxide doubly promoted by cobalt oxide and gold
Journal Article
·
· Journal of the Electrochemical Society
- Kyushu Univ., Kasuga, Fukuoka (Japan)
- Osaka Gas Co., Ltd. (Japan). Research and Development Center
Among the In{sub 2}O{sub 3}-based elements loaded with each of 12 metal oxides [0.5 weight percent (w/o) each], the Co{sub 3}O{sub 4}-added element was outstanding in sensitivity and selectiveness to CO at 250 C. Remarkably the sensing properties of this element could be increased further by the addition of Au (0.04 W/o). The element thus obtained, Au (0.04 w/o)-Co (0.5 w/o)-In{sub 2}O{sub 3}, gave excellent characteristics in sensitivity to CO, selectivity to CO against H{sub 2} and other selected gases, and responses rate at 250 C, giving promise of being applied as a CO sensor for safety control of gas appliances.
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 516888
- Journal Information:
- Journal of the Electrochemical Society, Vol. 144, Issue 6; Other Information: PBD: Jun 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
Selective CO detection by using indium oxide-based semiconductor gas sensor
Indium oxide-based gas sensor for selective detection of CO
Highly reduced MoO sub 3 /Al sub 2 O sub 3 catalysts II. Hydrogenolyses of cyclopropane, methylcyclopropane, and propane
Journal Article
·
Thu Feb 01 00:00:00 EST 1996
· Journal of the Electrochemical Society
·
OSTI ID:516888
+2 more
Indium oxide-based gas sensor for selective detection of CO
Conference
·
Tue Dec 31 00:00:00 EST 1996
·
OSTI ID:516888
+3 more
Highly reduced MoO sub 3 /Al sub 2 O sub 3 catalysts II. Hydrogenolyses of cyclopropane, methylcyclopropane, and propane
Journal Article
·
Sat Apr 01 00:00:00 EST 1989
· Journal of Catalysis; (USA)
·
OSTI ID:516888