A technical review and evaluation of the Millstone Unit 3 probabilistic safety study has been performed. It was determined that; (1) long-term damage indices (latent fatalities, person-rem, etc.) are dominated by late failure of the containment, (2) short-term damage indices (early fatalities, etc.) are dominated by bypass sequences for internally initiated events, while severe seismic sequences can also contribute significantly to early damage indices. These overall estimates of severe accident risk are extremely low compared with other societal sources of risk. Furthermore, the risks for Millstone-3 are comparable to risks from other nuclear plants at high population sites. Seismically induced accidents dominate the severe accident risks at Millstone-3. Potential mitigative features were shown not to be cost-effective for internal events. Value-impact analysis for seismic events showed that a manually actuated containment spray system might be cost-effective.