Investigation of air-infiltration characteristics and mechanisms for a townhouse. Final report

Technical Report ·
OSTI ID:5165883
Air infiltration measurements using a tracer-gas technique and the pressurization technique were performed on a three-bedroom townhouse having a gas-fired, forced-air furnace system, in order to quantify the amount of air infiltration due to various mechanisms. These mechanisms include combustion and draft-diverter air requirements, air leakage from supply-air ducts, and air leakage through the solid parts of the building envelope as well as air leakage through cracks around windows and doors. A thermographic survey was also performed in conjunction with pressurization of the structure, in an attempt to identify specific leaks. An apparatus for measuring the air permeability of building materials was used to analyze the significance of air permeation through solid building elements. Based on the findings of the study, general guidelines are presented for reducing air infiltration in residences.
Research Organization:
National Bureau of Standards, Washington, DC (USA)
OSTI ID:
5165883
Report Number(s):
PB-80-101355
Country of Publication:
United States
Language:
English

Similar Records

Air infiltration in buildings
Technical Report · Wed Oct 01 00:00:00 EDT 1980 · OSTI ID:6370839

Reducing Uncertainty for the DeltaQ Duct Leakage Test
Conference · Sat May 01 00:00:00 EDT 2004 · OSTI ID:825324

Infiltration and pressure differences induced by forced air systems in Florida residences
Conference · Sat Dec 31 23:00:00 EST 1988 · ASHRAE Transactions (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (USA) · OSTI ID:5783089