Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Size-selective monitoring techniques for particulate matter in California air. Final report

Technical Report ·
OSTI ID:5159029

After a review of the criteria for a suitable size-selective monitoring instrument, the dichotomous virtual impactor and the cyclone were selected for evaluation. A cyclone was designed with a 50% cutoff of 3.5 micrometers at 15 l/min. The cyclone and the Sierra Model 243 dichotomous virtual impactor were tested extensively with monodisperse aerosol including both solid and liquid particles. Detailed measurements were made of particle deposition in the samplers as a function of particle size and air flow rate. Wall losses, reentrainment and uniformity of filter deposits were determined. The results of the tests show that both samplers are satisfactory for monitoring purposes.

Research Organization:
California Dept. of Health, Berkeley (USA). Air and Industrial Hygiene Lab.
OSTI ID:
5159029
Report Number(s):
PB-80-113731
Country of Publication:
United States
Language:
English