Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Pulse transformer R and D for NLC klystron pulse modulator

Conference ·
OSTI ID:515596

The authors have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and requires a larger core size. After making a tradeoff among these parameters carefully, a conventional pulse transformer with a rise time of 250ns and a pulse droop of 3.6% has been designed and built. The transmission characteristics and pulse time-response were measured. The data were compared with the model. The agreement with the model was good when the measured values were used in the model simulation. The results of the high voltage tests using a klystron load are also presented.

Research Organization:
Stanford Linear Accelerator Center, Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Energy Research, Washington, DC (United States)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
515596
Report Number(s):
SLAC-PUB--7583; CONF-9706113--7; ON: DE97008347
Country of Publication:
United States
Language:
English

Similar Records

Development of the pulse transformer for NLC klystron pulse modulator
Conference · Thu May 01 00:00:00 EDT 1997 · OSTI ID:522743

Analyses of Klystron Modulator Approaches for NLC
Technical Report · Thu Aug 24 00:00:00 EDT 2000 · OSTI ID:763848

Modulator R and D for the NLC