Results of a study to refine the Phase I conceptual design of a 100 MWe sodium cooled central receiver power plant to incorporate improvements in performance and cost are presented in detail. Topics include a solar receiver panel configuration analysis, receiver flow control system cost reduction, storage subsystem design improvements, operating mode analysis, system annual performance analysis, refined conceptual design, and refined plant cost estimate. Appendices include (a) receiver loss analysis code (PANELGR2), (b) PANELGR2 output for selected grouping scheme, (c) component cooldown analysis (initial uniform temperature), (d) component cooldown analysis (initial nonuniform temperature), (e) temperature cycling considerations in the downcomer pipe, (f) trickle flow scheme for short term standby, and (g) computer program listing for system annual performance analysis. (WHK)