CFB sorbent selection enhances performance
Journal Article
·
· Power Engineering (Barrington)
OSTI ID:514510
The quality and particle size of the sorbent has a direct influence on the efficiency of sulfur dioxide (SO{sub 2}) removal in a circulating fluidized bed (CFB) boiler. This report outlines tests and subsequent operation of a CFB unit at the University of North Carolina at Chapel Hill Cogeneration Facility (UNC-CH) that proved how dramatically a change in sorbent can change the efficiency of performance.
- OSTI ID:
- 514510
- Journal Information:
- Power Engineering (Barrington), Journal Name: Power Engineering (Barrington) Journal Issue: 7 Vol. 101; ISSN 0032-5961; ISSN POENAI
- Country of Publication:
- United States
- Language:
- English