Title: Failure analyses of filament-wound graphite/epoxy cylinders under biaxial loading

Journal Article · · SAMPE Q.; (United States)
OSTI ID:5136451

This paper discusses macroscopic and microscopic failure behavior of filament-wound (90/+/-20)/sub s/ graphite/epoxy thin-wall cylinders subjected to biaxial loading. Experimental results, elastic constants, and strengths are compared with analytical predictions. The Tsai-Wu failure criterion gave reasonable agreement between theoretical and experimental results. Specimens machined from failed cylinders were examined using scanning electron microscopy. Interply and intraply cracking were observed. These microscopic failure mechanisms are not accounted for in any failure criterion available in the literature. 6 references, 8 figures, 2 tables.

Research Organization:
Westinghouse R and D Center, Pittsburgh, PA
OSTI ID:
5136451
Journal Information:
SAMPE Q.; (United States), Vol. 17:1
Country of Publication:
United States
Language:
English