Coefficient of thermal expansion of fluorinert as a function of volume percent absorbed air
The relationship between the coefficient of volumetric thermal expansion of liquid Fluorinert FC-86 and the volume percent of absorbed air was examined experimentally. A special test apparatus was built for this purpose. A floating liquid seal was used to isolate the Fluorinert sample from the atmosphere. This prevented gas absorption during thermal cycling yet allowed the sample to expand and contract freely during testing. It was found that the coefficient of thermal expansion is not influenced by the percentage of absorbed air.