Non-rigid summing of gated PET via optical flow

Conference ·
OSTI ID:513206
; ;  [1]
  1. Lawrence Berkeley National Lab., CA (United States)

A method for summing together datasets from gated cardiac PET acquisitions is described. Optical flow techniques are used to accurately model non-rigid motion present during the cardiac cycle so that a one-to-one mapping is found between each voxel of two gated volumes. Using this mapping, image summing can take place, producing a composite dataset with improved statistics and reduced motion-induced blur. Results using a data from a gated cardiac study on a dog are presented.

DOE Contract Number:
AC03-76SF00098
OSTI ID:
513206
Report Number(s):
CONF-961123--; CNN: Grant HL25840
Country of Publication:
United States
Language:
English

Similar Records

Respiratory compensation in cardiac PET using doubly-gated acquisitions
Journal Article · Thu May 01 00:00:00 EDT 1997 · Journal of Nuclear Medicine · OSTI ID:563341

Compensation for respiratory motion in cardiac PET - A feasibility study
Journal Article · Wed May 01 00:00:00 EDT 1996 · Journal of Nuclear Medicine · OSTI ID:447768

Acquisition and automated 3-D segmentation of respiratory/cardiac-gated PET transmission images
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:513210