Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Analysis of LOFT pressurizer spray and surge nozzles to include a 450/sup 0/F step transient

Technical Report ·
DOI:https://doi.org/10.2172/5125000· OSTI ID:5125000
This report presents the analysis of the LOFT pressurizer spray and surge nozzles to include a 450/sup 0/F step thermal transient. Previous analysis performed under subcontract by Basic Technology Incorporated was utilized where applicable. The SAASIII finite element computer program was used to determine stress distributions in the nozzles due to the step transient. Computer results were then incorporated in the necessary additional calculations to ascertain that stress limitations were not exceeded. The results of the analysis indicate that both the spray and surge nozzles will be within stress allowables prescribed by subsubarticle NB-3220 of the 1974 edition of the ASME Boiler and Pressure Vessel Code when subjected to currently known design, normal operating, upset, emergency, and faulted condition loads.
Research Organization:
Idaho National Engineering Lab., Idaho Falls (USA)
DOE Contract Number:
EY-76-C-07-1570
OSTI ID:
5125000
Report Number(s):
LTR-1144-38; RE-A-78-012
Country of Publication:
United States
Language:
English