Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Monitored Retrievable Storage conceptual system study: concrete storage casks

Technical Report ·
OSTI ID:5123296
This report presents design concepts and cost estimates for the Monitored Retrievable Storage facility which uses concrete silos for storage. Two separate scenarios are considered: the first is the storage of spent fuel assemblies and the second is the storage of wastes generated during the reprocessing of spent fuel and does not consider spent fuel storage. Two storage options for each scenario were evaluated. One is for maximum throughput of fuel or waste at 1800 MTU/y and a facility storage capacity of 15,000 MTU. The other option is for a maximum throughput of fuel or waste at 3000 MTU/y and a facility storage capacity of 72,000 MTU. The construction and operating costs, as well as the life-cycle costs for both scenarios and both the 1800 and 3000 MTU/y throughput rates are summarized. Drawings defining the facility and equipment that are unique to the silo storage concept are included. 26 figures, 34 tables.
Research Organization:
Boeing Engineering Co., Seattle, WA (USA)
OSTI ID:
5123296
Report Number(s):
BEC-MRS-3302; ON: DE84008828
Country of Publication:
United States
Language:
English