A real time bunch length monitor in the TRISTAN AR
Conference
·
· AIP Conference Proceedings (American Institute of Physics); (United States)
OSTI ID:5120088
- KEK, Oho 1-1, Tsukuba-shi, Ibaraki-ken (305 Japan)
The bunch length can be measured by the comparison of two Fourier components of the beam. This technique has been applied to an electron bunch in the TRISTAN Accumulation Ring (AR). Since the rms bunch length of the AR is in a range from 1 cm to 4 cm, detected frequencies are in the Gigaherzt region. However, the detected frequency is restricted by the cutoff frequency of vacuum pipe, which imposes high resolution requirements on a detector. Preliminary experiments with a spectrum analyzer show that it is possible to measure the bunch length in real time with a stripline electrode.
- OSTI ID:
- 5120088
- Report Number(s):
- CONF-9010267--
- Conference Information:
- Journal Name: AIP Conference Proceedings (American Institute of Physics); (United States) Journal Volume: 229:1
- Country of Publication:
- United States
- Language:
- English
Similar Records
Longitudinal bunch deformation of a multi-bunched beam in the TRISTAN Accumulation Ring
The longitudinal feedback system in TRISTAN AR
A Main Ring bunch length monitor by detecting two frequency components of the beam
Journal Article
·
Tue Dec 31 23:00:00 EST 1996
· AIP Conference Proceedings
·
OSTI ID:526829
The longitudinal feedback system in TRISTAN AR
Conference
·
Tue Oct 01 00:00:00 EDT 1985
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:6344706
A Main Ring bunch length monitor by detecting two frequency components of the beam
Technical Report
·
Fri Jun 02 00:00:00 EDT 1989
·
OSTI ID:5757593