skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Worn blades may have caused turbine failure

Journal Article · · Nuclear News
OSTI ID:508480

Detroit Edison Co.`s decision not to replace eighth-stage blades in low-pressure turbine number three may have caused the event that damaged the turbine, generator, and exciter at Fermi-2 on December 25, 1993. This finding is included in the February 7 report of the Nuclear Regulatory Commission`s Augmented Inspection Teams (AIT). GEC Turbine Generations Ltd. of England, manufacturer of the turbine, had recommended replacing the blades during the plant`s third refueling outage in September 1992. Detroit Edison chose not to do so, stating in its report, {open_quotes}This wear is of the same magnitude as that noticed in RF01 [refueling outage 1] and it is not necessary to record this wear since all blades will be changed in RF04 [refueling outage 4].{close_quotes}

OSTI ID:
508480
Journal Information:
Nuclear News, Vol. 37, Issue 5; Other Information: PBD: Apr 1994
Country of Publication:
United States
Language:
English

Similar Records

Root cause analysis of low pressure turbine blade failure
Conference · Fri Nov 01 00:00:00 EST 1996 · OSTI ID:508480

Cumberland last stage blade failure investigation
Conference · Sun Dec 31 00:00:00 EST 1995 · OSTI ID:508480

Detect, troubleshoot gas-turbine blade failures
Journal Article · Fri Dec 01 00:00:00 EST 1995 · Power (New York) · OSTI ID:508480