Title: Improving gas dehydrator efficiency; Glycol losses from dehydrator solved by mist eliminator

Journal Article · · Pipeline and Gas Journal; (USA)
OSTI ID:5067558
;  [1];  [2]
  1. Winnie Pipeline Co., Winnie, TX (US)
  2. ACS Industries Inc., Houston, TX (US)

Triethylene glycol losses from a natural gas dehydrator unit were costing Winnie Pipeline Co. well over $100/day. Several possible causes had been investigated, and a second, smaller unit had been added because insufficient capacity was thought to cause glycol carryover from the contactor. Eventually, glycol losses were virtually eliminated by replacing the standard mist eliminator pad in the top of the contactor tower with a higher-efficiency type. Use of this type of pad is discussed in this paper.