skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Diagnostic measurement of a combustion chamber to achieve environmental and output parameters of pulverized hard coal boilers

Conference ·
OSTI ID:504657
; ;  [1]
  1. Technical Univ. of Ostrava (Czech Republic). Dept. of Energetics

The NO{sub x} and CO emissions of the three Benzon pulverized boilers with turbulent wall burners under the ceiling of a combustion chamber were exceeded because of an unstable combustion process. Through diagnostic measurements during a combustion chamber operation and by isothermal measurement in front of the opening of the burner the cause was found out to be the wrong type and the configuration of burners. A significant improvement was reached by changing the turbulence parameter of burners, their mutual position and the tercial air introduction into combustion chamber. It was proved by isothermal measurement in the burner`s area and by diagnostic measurement in a combustion chamber with the help of cooled probes for temperature measurement and taking samples for combustion products analysis. At the same time the influence of fuel feeding on flame pulsation was verified as well as pulsation removal by changing the frequency of the chamber feeder of coal powder. More than 30 measurements for different combustion and output regimes are giving results which determine the optimal burning regime with minimal NO{sub x} and CO levels and the remains of unburnt matter in fly ash for the highest reachable efficiency of the boiler.

OSTI ID:
504657
Report Number(s):
CONF-960954-; TRN: IM9733%%72
Resource Relation:
Conference: 13. annual international Pittsburgh coal conference, Pittsburgh, PA (United States), 3-7 Sep 1996; Other Information: PBD: 1996; Related Information: Is Part Of Thirteenth annual international Pittsburgh coal conference: Proceedings. Volume 1; Chiang, S.H. [ed.]; PB: 786 p.
Country of Publication:
United States