Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Performance of PRD-66 hot gas candle filters in the AEP/TIDD PFBC facility

Conference ·
OSTI ID:504652
 [1]
  1. DuPont Lanxide Composites, Inc., Newark, DE (United States)
The performance of PRD-66 hot gas filters in American Electric Power`s TIDD PFBC facility is described. PRD-66 hot gas filters are made of an all-oxide composition with a unique layered microstructure which lends corrosion resistance, high temperature stability and excellent resistance to thermal shock damage. The development of the PRD-66 material into a hot gas candle filter is recounted. Testing which guided filter development prior to exposure in the AEP/TIDD PFBC system is discussed. Future plans for testing in coal combustion and other industrial applications are described.
Sponsoring Organization:
USDOE Morgantown Energy Technology Center, WV (United States)
DOE Contract Number:
AC21-94MC31214
OSTI ID:
504652
Report Number(s):
CONF-960954--
Country of Publication:
United States
Language:
English

Similar Records

Development and Testing of PRD-66 Hot Gas Filters
Technical Report · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:419377

PRD-66 Gas Filter Development
Conference · Tue Jul 01 00:00:00 EDT 1997 · OSTI ID:620958

Development and testing of PRD-6 hot gas filters
Conference · Thu Nov 30 23:00:00 EST 1995 · OSTI ID:150943