Stevens Home, Rancho Santa Fe, California: solar-energy-system performance evaluation, October 1981-April 1982
Technical Report
·
OSTI ID:5045957
The Stevens Home in California is a single family residence whose active solar energy system is designed to supply 70% of the hot water load. The system is equipped with 68 square feet of flat plate collectors, a 120-gallon solar preheat water tank, and a 40-gallon propane water heater. The solar fraction predicted by computer simulation and measured were the same, 44%. The system solar savings ratio, conventional fuel savings, and solar system coefficient of performance for the period covered are given. Monthly performance data are tabulated for the overall system and for the collector, storage, and domestic hot water subsystems. System operation is illustrated for a typical day by graphs of the temperatures at collector array, inlet and outlet, and at the preheat tank, and of water consumption. The typical operating sequence and solar energy use and heat losses are also graphed. (LEW)
- Research Organization:
- Automation Industries, Inc., Silver Spring, MD (USA). Vitro Labs. Div.
- DOE Contract Number:
- AC01-79CS30027
- OSTI ID:
- 5045957
- Report Number(s):
- SOLAR/1118-82/14; ON: DE82021698
- Country of Publication:
- United States
- Language:
- English
Similar Records
Solar-energy-system performance evaluation update: Stevens Home, Rancho Sante Fe, California, May 1982-April 1983
Williamson Home, Ipswich, Massachusetts solar-energy-system performance evaluation, November 1981-April 1982
Isakson Home, Anoka, Minnesota solar-energy-system performance evaluation, August 1981-March 1982
Technical Report
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:5161854
Williamson Home, Ipswich, Massachusetts solar-energy-system performance evaluation, November 1981-April 1982
Technical Report
·
Thu Dec 31 23:00:00 EST 1981
·
OSTI ID:5094106
Isakson Home, Anoka, Minnesota solar-energy-system performance evaluation, August 1981-March 1982
Technical Report
·
Thu Dec 31 23:00:00 EST 1981
·
OSTI ID:5094090
Related Subjects
14 SOLAR ENERGY
140907* -- Solar Thermal Utilization-- Water Heating
APPLIANCES
BUILDINGS
BURNERS
CALIFORNIA
COEFFICIENT OF PERFORMANCE
CONTAINERS
DATA
EFFICIENCY
ENERGY CONSUMPTION
ENERGY LOSSES
ENERGY YIELD
EQUIPMENT
EXPERIMENTAL DATA
FEDERAL REGION IX
GAS BURNERS
HEAT LOSSES
HEATERS
HOUSES
INFORMATION
LOSSES
NORTH AMERICA
NUMERICAL DATA
OPERATION
PERFORMANCE
RESIDENTIAL BUILDINGS
SOLAR COLLECTORS
SOLAR EQUIPMENT
SOLAR FRACTION
SOLAR WATER HEATERS
TANKS
TEMPERATURE DISTRIBUTION
USA
WATER HEATERS
WATER REQUIREMENTS
YIELDS
140907* -- Solar Thermal Utilization-- Water Heating
APPLIANCES
BUILDINGS
BURNERS
CALIFORNIA
COEFFICIENT OF PERFORMANCE
CONTAINERS
DATA
EFFICIENCY
ENERGY CONSUMPTION
ENERGY LOSSES
ENERGY YIELD
EQUIPMENT
EXPERIMENTAL DATA
FEDERAL REGION IX
GAS BURNERS
HEAT LOSSES
HEATERS
HOUSES
INFORMATION
LOSSES
NORTH AMERICA
NUMERICAL DATA
OPERATION
PERFORMANCE
RESIDENTIAL BUILDINGS
SOLAR COLLECTORS
SOLAR EQUIPMENT
SOLAR FRACTION
SOLAR WATER HEATERS
TANKS
TEMPERATURE DISTRIBUTION
USA
WATER HEATERS
WATER REQUIREMENTS
YIELDS