Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Teleseismic p-wave amplitudes and spectra at nts and at the shoal site as compared to those observed in eastern north america. Preliminary technical report

Technical Report ·
OSTI ID:5042649

Three Special Data Collection System (SDCS) stations were deployed at NTS to Measure magnitude residuals and spectral differences relative to two Eastern United States (EUS) stations in order to determine the degree of anelastic attenuation under NTS. At the NTS station located on the Climax stock (OB2NV), the average teleseismic body-wave magnitude is .13 magnitude units (m.u.) lower than at HNME and .19 m.u. lower than at RKON. The magnitudes at the two Pahute Mesa sites average .25 m.u. higher than at OB2NV, but calculations show that most of the difference can be attributed to site amplification by low velocity volcanics under Pahute Mesa. At all NTS sites the high frequency content of P-waves is less than at RKON; the difference is statistically significant for two of the three NTS stations, and marginally significant at the third. Measurements at the site of the SHOAL explosion yield similar figures, showing lower high frequency content and lower magnitudes of P-waves relative to EUS. The above results are indicative of anelastic losses of body-waves traversing the mantle under both test sites.

Research Organization:
Teledyne Geotech, Alexandria, Va. (USA). Seismic Data Lab.
OSTI ID:
5042649
Report Number(s):
AD-045096; SDAC-TR-77-9
Country of Publication:
United States
Language:
English