Electrical Contact Performance Degradation in Electromechanical Components

Conference ·
OSTI ID:5041

Detailed materials evaluations have been performed for MC2969 Intent Stronglink switch monitor circuit parts returned from the field out of retired weapon systems. Evaluations of local contact resistance, surface chemical composition and surface roughness and wear have been determined as a function of component level contact loop resistance testing position. Several degradation mechanisms have been identified and correlated with the component level measurements. Operational degradation produces surface smoothing and wear with each actuation of the monitor circuit, while aging degradation is observed in the segregation of contaminant species and alloy constituent elements to the surface in the stressed wear regions.

Research Organization:
Sandia National Labs., Albuquerque, NM (US); Sandia National Labs., Livermore, CA (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
5041
Report Number(s):
SAND99-0698C
Country of Publication:
United States
Language:
English

Similar Records

A hardware review of electrical contact aging and performance in electromechanical stronglinks
Conference · Mon Sep 01 00:00:00 EDT 1997 · OSTI ID:634129

Surface Micromachined Components for a Safety Subsystem Application
Conference · Wed Mar 03 23:00:00 EST 1999 · OSTI ID:4238

Thermal rectification in similar and dissimilar metal contacts
Journal Article · Thu Jan 31 23:00:00 EST 1991 · Journal of Heat Transfer (Transcations of the ASME (American Society of Mechanical Engineers), Series C); (United States) · OSTI ID:5644008