Fabric filter testing at the TVA Atmospheric Fluidized-bed Combustion (AFBC) Pilot Plant

Technical Report ·
OSTI ID:5040762
Experience with fluidized bed combustion (FBC) units on a research and industrial scale has indicated that FBC power plants could be a viable alternative to pulverized-coal power plants with wet limestone scrubbers or spray dryers. To provide design confidence and the flexibility to evaluate process improvements, the Tennessee Valley Authority constructed a 20-MW(e) AFBC (bubbling bed) Pilot Plant. Subseqently, EPRI and Southern Research Institute entered into a program to monitor the performance of the fabric filter at the pilot plant. The objective of the program was to determine if unique characteristics of AFBC operation or emissions would require special design criteria or operating procedures in the application of fabric filtration to utility-size AFBC boilers. With reverse-gas cleaning the fabric filter experienced high tubesheet pressure drop while operating at low filtering air-to-cloth values and with low residual dustcake areal densities compared to fabric filters downstream from pulverized-coal boilers. This implied that the AFBC fly ash had properties distinct from those of pulverized-coal fly ash. Implementaion of reverse-gas cleaning with sonic assistance resulted in lower operating pressure drops at higher filtering air-to-cloth values, although slightly higher than comparable data from baghouses filtering pulverized-coal fly ash. Fly ash analyses showed that the AFBC ash particles are generally smaller, more irregualr in shape, and the dustcakes are lighter and more porous than those formed from pulverized-coal fly ashes. 8 refs., 18 figs., 7 tabs.
Research Organization:
Electric Power Research Inst., Palo Alto, CA (USA); Southern Research Inst., Birmingham, AL (USA)
OSTI ID:
5040762
Report Number(s):
EPRI-CS-5837; ON: TI88011431
Country of Publication:
United States
Language:
English

Similar Records

Arapahoe low-sulfur coal fabric filter pilot plant. Volume 2. Characterization and reverse-gas cleaning tests, October 1980-April 1982. Final report
Technical Report · Mon Jul 01 00:00:00 EDT 1985 · OSTI ID:5537893

Field tests of fabric filters on full-scale coal-fired utility boilers. Volume 1. Martin Drake Unit 6, Ray D. Nixon Unit 1, Cherokee Unit 3, Cameo Unit 2, and Arapahoe Unit 3
Technical Report · Tue Oct 01 00:00:00 EDT 1985 · OSTI ID:5125621

Filtration properties of fly ash from fluidized bed combustion
Journal Article · Sat Oct 31 23:00:00 EST 1987 · J. Air Pollut. Control Assoc.; (United States) · OSTI ID:5410205